Monday 9 May 2011

Easy Guide to Pathology Lab Design


Easy Guide to Pathology Lab Design



Planning Pathology labs including microbiology, biochemistry and haematology should be fairly simple and straight forward. But we know from experience that if careful thought is not given at the design and planning stage, the simplest of things can and most probably will go wrong.

So what do we really need to watch out for? Although designing a hospital is a painstaking procedure best left to the professionals, still the following three basic aspects pertaining to hospital lab design need to be remembered:

Lab Benching
The material and surface are your first consideration. For labs that deal with strong chemicals, Trespa (a brand name and material by Trespa) is the best choice in the market. Within Trespa, there are two types – Trespa Athlon and Trespa TopLab (both registered trademarks of Trespa) .

Athlon is more impact and scratch resistant while TopLab is more chemical resistant.

The other important aspect is the height & depth of the lab benching. Generally recommended height is 920mm for standing and depths are 600mm or 750mm but you will come across situations where an 800mm deep benching is required. This maybe needed to accommodate a deep equipment above or below the lab benching.

You need to remember that with a 750mm deep benching the space below is less than that due to the back panel which hides the services running behind such as electrical cables and water and drain pipes. Make sure you know the height and depth of your under bench fridges and cupboards as well as how big and heavy your worktop mounted analysers and centrifuges are.

Services
The second important consideration is the quantity and type of services required for each piece of equipment dotted around the labs and the need for power, data, potable or special water (distilled, de-ionised, RO), lab gasses, sinks and drainage. Some of these are normally placed at regular measurements around the labs depending on the activities being carried out.

Environment
Depending on chemicals and equipment used, fumes and heat dissipation (such as -70 degree freezers and blood fridges) issues can be significant. This has to be dealt with ventilation and convection cooling/air-conditioning.

While on ventilation, attention needs to be given to the fume cabinets and safety cabinets that require very careful and purpose built exhausts. These can be re-circulating (requiring specific filtration) or exhaust type that take the extract out to a certain level outside the building.

As experts in the field for a long while we strongly encourage hospital design students and newbies to get in touch with us. We are happy to assist upcoming and budding designers of the future!

speaker

About the Author:
Harry McQue is a hospital design manager with three masters degrees including business management and information technology. Harry has 15 years of international experience ranging from working on hospital projects in Dubai (Middle East) to over £1 Billion hospital projects in the UK. You can benefit from his experience at: www.hospitaldesigntips.com. If there are topics that you would like his advice on, you can get in touch on Harry_Mcque@HospitalDesignTips.com

Copyright 2008, http://www.hospitaldesigntips.com. Reproduction by permission only. Please contact harry_mcque@hospitaldesigntips.com for permissions and advice.